Snap-on bulk current injection probe for industrial products

Designed for conducted immunity testing primarily in the frequency range of 150 kHz to 230 MHz, in accordance with the standard IEC/EN61000-4-6.

**Product Overview** The TBBCI1-200K280 is a Snap-On bulk current injection probe. The BCI probe is designed primarily for conductive immunity testing in the frequency range of 150 kHz to 230 MHz, in accordance with the standard IEC / EN 61000-4-6. The insertion loss is 8 dB over most of the bandwidth, fully complying with the insertion loss specifications of IEC / EN 61000-4-6. The probe is individually characterized and can be used in the frequency range of 10 kHz to 300 MHz. According to IEC/EN 61000-4-6, it can inject into conductive immunity test setups at severity levels 1, 2, 3, and level X, up to 30V. This probe can also be used for RF current monitoring applications. The opening of the RF current monitoring probe is 27 mm. The standard insertion loss is 8 dB, and the standard transfer impedance is 26 dB ohms.

  • Other electronic measuring instruments
  • EMC Testing
  • Current Injection Probe

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Snap-on bulk current injection probe for automotive products

Designed for conducted immunity testing of automotive products primarily in the frequency range of 1MHz to 400MHz according to standard ISO11452-4.

**Product Overview** The TBBCI1-800K420 is a Snap-On bulk current injection probe. The BCI probe is designed primarily for conducting immunity testing of automotive products in accordance with standard ISO11452-4, mainly in the frequency range of 1 MHz to 400 MHz. The insertion loss is 5 dB over most of the bandwidth. It complies with the insertion loss specifications of ISO11452-4 in the frequency range of 250 kHz to 230 MHz. The probe is individually characterized and can be used in the frequency range of 10 kHz to 450 MHz. This probe can be used for injections of severity I (60mA), II (100mA), III (150mA), IV (200mA), and customer-specific severity V (up to 350 mA). This probe can also be used for RF current monitoring applications. The opening of the RF current monitoring probe is 27 mm. The standard insertion loss is 5 dB, and the standard transfer impedance is 26 dB ohms.